LD series of intelligent electromagnetic flow meter is a high performance, high reliability flow meter for measuring the volumetric flow of conductive liquids and slurries in closed conduits. Widely used in iron and steel, electric power, petroleum, chemical industry, coal, metallurgy, Papermaking, water supply and drainage, food, medicine and other industries
Product Name | Electromagnetic flow meter | |||
Diameter | DN10~DN2000mm | |||
Flow range | 0-9999 m3/H | |||
Signal output | Pulse and 4~20mA and RS485 or Hart ; (if use lithium battery, without signal output) | |||
Accuracy | ±0.5% ±2mm/s (flowrate < 1m/s) | |||
Power supply | 220VAC/24VDC/lithium battery | |||
Medium temperature | IP68:-25 - 180ºC IP65:-10 - 80ºC | |||
Nominal pressure | 1.0MPa | 1.6MPa | 2.5MPa | 4.0MPa |
DN15-DN500 | DN15-DN500 | DN15-DN500 | DN15-DN50 | |
Lining Material | Chloroprene rubber (CR), Polytetrafluoroethylene (PTFE/F4), Fluorinated ethylene propylene (FEP/F46), Te flon(PFA) |
|||
Electrode Material | 316L Stainless Steel, Hastelloy C, Hastelloy B, Ti, Ta, Pt | |||
Medium | Conductive liquids, strong acids, strong alkali liquids, condensed water | |||
Order information : Pipe size , measured medium, working pressure |
Flow Meter Types | Type of Liquid Measured | Range(mm) | Output | Accuract | Features | Advantages | Applications |
Electromagnetic Flow Meter | Conductive liquids (e.g., water, wastewater, slurries) | DN10-3000 | Pulse, Analog, Frequency, alarm, wireless | ±0.2%- ±0.5% | Non-intrusive, no moving parts, high accuracy | No pressure drop, suitable for dirty/corrosive fluids | Water and wastewater treatment, chemical processing, mining, paper industry |
Ultrasonic Flow Meter | All types of liquids (clean/dirty, conductive/non-conductive) | DN15-6000 | Analog, digital, pulse | ±0.5%-±1.0% | Non-invasive, clamp-on or inline, uses sound waves | No pressure drop, suitable for large diameter pipes | Water and wastewater, gasoline, food and beverage |
Liquid Turbine Flow Meter | Clean, low-viscosity liquids (e.g., water, light oils) | DN4-200 | Pulse,analog, digital | ±0.5% - ±1.0% | Mechanical, rotating turbine, requires clean fluids | High accuracy, good repeatability | Fuel measurement, chemical processing, water distribution |
Coriolis Mass Flow Meter | Any liquid, including slurries and high-viscosity fluids | DN3-250 | Pulse, analog, digital | ±0.1%~±0.5% | Measures mass flow using Coriolis effect, high accuracy | Direct mass flow measurement, measures density and temperature | Chemical processing, food and beverage, pharmaceuticals |
Oval Gear Flow Meter | Viscous and non-conductive liquids (e.g., oils, syrups) | DN10-150 | Analog, digital, pulse | ±0.5%-±1.0% | Mechanical, intermeshing gears, accurate for viscous fluids | High accuracy, good for high-viscosity fluids | Oil and gas, food and beverage, chemical processing |
Vortex Flow Meter | Liquids, gases, and steam | DN15-200 | Pulse,analog, digital | ±1.5% | Measures vortices shed by a bluff body, no moving parts | Suitable for high-temperature/pressure, various fluids | Steam flow measurement, HVAC systems, chemical processing |
Rotameter/Float Flow Meter | Low-viscosity liquids and gases | DN15-500 | Analog,digital | ±0.5% - ±1.0% | Simple, mechanical with float in a tapered tube, direct reading scale | Simple, low cost, no power required | Laboratory measurements, water treatment, air sampling |
Double Rotor Flow Meter | Lliquids with varying viscosities, such as thin oil, light oil, or crude oil with high sand and water content. | DN40-DN250 | Analog, Pulse, RS485 | 0.5% / 0.2% | Handles large viscosity range; high flow rate; long service life; minimal pressure loss; remote transmission up to 1,000 meters with pulse signal output. | Stable operation; low noise; minimal wear; high accuracy; allows fine particles to pass; prevents meter sticking. | Measurement of various oils in industrial processes; high viscosity liquids in chemical and petrochemical industries; crude oil with sand and water; remote monitoring. |
Volumetric Flow Meter | Various liquids | 230-380-750-1300L/min | ±0.2% | Measures volume, includes positive displacement meters | Accurate for total volume measurement, handles viscous fluids | Custody transfer, fuel measurement, chemical dosing | |
Open Channel Ultrasonic Flow Meter | Liquids in open channels (e.g., rivers, streams, wastewater) | 0.1l/s~99999.99m/h | Analog, Relay,RS485, RS232, MODBUS | 0.25%- 0.5%F.S. | Uses ultrasonic waves, non-contact measurement | Suitable for open channels, no obstruction to flow | Wastewater treatment, irrigation channels, environmental monitoring |
Open Channel Radar Flow Meter | Liquids in open channels | 40m | Analog, digital, wireless | ±0.01m/s,±2mm | Uses radar waves, non-contact measurement | High accuracy in harsh conditions, suitable for large channels | Flood monitoring, irrigation systems, environmental studies |